Specifications
Function Range Accuracy (of reading)
2.000 ACA ± (2.5% + 10 digits)
20.00 ACA ± (2.5% + 4 digits)
200.0 ACA ± (2.5% + 4 digits)
AC Current
400 ACA ± (3.0% + 5 digits)
200.0mV, ± (1.5% + 30 digits)
2.000V
20.00V
200.0V
± (1.5% + 3 digits)
AC Voltage
600V ± (2.0% + 4 digits)
200.0mV ± (0.5% + 5 digits)
2.000V
20.00V
200.0V
± (1.2% + 3 digits)
DC Voltage
600V ± (1.5% + 3 digits)
200.0 ± (1.0% + 4 digits)
2.000k
20.00k
200.0k
± (1.5% + 2 digits)
2.000M ± (2.0% + 3 digits)
Resistance Ω
20.00M ± (3.0% + 5 digits)
Jaw size 0.9" (23mm) approx.
Display 3-1/2 digits (2000 counts) LCD
Continuity Audible tone < 120Ω approx.
Diode Test Open circuit voltage < 1.5VDC;
Test current 0.3mA (typical)
AC V bandwidth 50Hz to 400Hz
AC A bandwidth 50/60Hz
Low battery indication “BAT” is displayed
Overrange indication “OL” is displayed
Auto Power OFF After 15 minutes
Measurement rate 2 per second, nominal
Input Impedance 7.8MΩ (V DC and V AC)
Operating Temperature 41ºF to 104ºF (5ºC to 40ºC)
Storage Temperature -4
o
F to 140
o
F (-20
o
C to 60
o
C)
Operating Humidity Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at
104ºF(40ºC)
Storage Humidity <80%
Operating Altitude 6560ft. (2000meters)
Batteries (2) 1.5V AAA batteries
Weight 0.44lb (200g)
Size 7.87” x 1.97” x 1.38” (200x50x35mm)
Safety For indoor use and in accordance with the requirements for
double insulation to IEC1010-1 (1995): EN61010-1 (1995)
Overvoltage Category III, Pollution Degree 2.